S19 XP+ Hyd

Short Description:


Product Detail

Product Tags

| Performance Curves


 

1. Hashrate vs. Inlet Coolant Temperature

 

2. Power Efficiency vs. Inlet Coolant Temperature


(1-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%.

| Specifications


 

Product Glance Value
Model S19 XP+ Hyd.
Crypto algorithm/coins SHA256 | BTC/BCH/BSV
Typical hashrate, TH/s(2-1) 279
Power on wall @35°C(2-2), Watt(2-1) 5,301
Power efficiency on wall @35°C(2-2), J/TH(2-1) 19

 

Detailed Characteristics Value
Power Supply
Phase 3
Input voltage, Volt(2-1) 380~415
Input Frequency Range, Hz 50~60
Input max current, Amp 12
Hardware Configuration
Networking connection mode RJ45 Ethernet 10/100M
Server Size (Length*Width*Height, w/o package), mm 339*173*207
Server Size (Length*Width*Height, with package), mm 570*316*430
Net weight, kg(3-2) 12.3
Gross weight, kg 13.6
Environment Requirements
Inlet coolant temperature,°C
20~50
Coolant flow, L/min
8.0~10.0
Coolant pressure, bar
≤3.5
Working coolant(3-2)
Antifreeze/ Pure water/Deionized water
Coolant pH value
Antifreeze: 7.0~9.0
Pure water: 6.5~7.5
Deionized water:8.5~9.5
Diameter of coolant pipe connector, mm
OD10
Storage temperature,°C -20~70
Operation humidity(non-condensing) , RH 10~90%

Notes:

(2-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.

(2-2) Inlet coolant temperature.

(3-1) Caution: Wrong input voltage may cause server damaged.

(3-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Hydro Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!