S21+ Hyd
| Specifications
Product Glance | Value |
Model | S21+ Hyd. |
Version | (319T-10) |
Crypto algorithm/coins | SHA256|BTC/BCH/BSV |
Typical hashrate, TH/s(1-1) | 319 |
Power on wall @35℃(1-2), Watt(1-1) | 4785 |
Power efficiency on wall@35℃(1-2), J/T(1-1) | 15.0 |
Detailed Characteristics | Value |
Power Supply | |
Phase | 3 |
Input voltage, Volt(2-1) | 380~415 |
Input frequency range, Hz | 50~60 |
Input max current, Amp | 12 |
Hardware Configuration | |
Networking connection mode | RJ45 Ethernet 10/100M |
Server size (length*width*height, w/o package), mm | 339*173*207 |
Server size (length*width*height, with package), mm | 570*316*430 |
Environment Requirements | |
Inlet coolant temperature, °C | 20~50 |
Coolant flow, L/min | 8.0~10.0 |
Coolant pressure, bar | ≤3.5 |
Working coolant(2-2) | Antifreeze/ Pure water/Deionized water |
Coolant pH value | Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water:8.5~9.5 |
Diameter of coolant pipe connector, mm | 0D10 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
Notes:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to “ANTSPACE HK3 Water Cooling Container & Dry-Wet Tower Product Manual”, Chapter 9, Article 3, Point 6, “Maintenance of Coolant”!
| Performance Curves
- Hashrate vs. Inlet Coolant Temperature
- Power Efficiency vs. Inlet Coolant Temperature
(3-1) The hashrate value, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power efficiency on wall fluctuate by ±5%